Quick Links

Español | Available From: Grainger US Acklands Grainger Grainger Mexico

Header

Navigation

Content

Item Details - 10C389

DaytonCentrifugal Belt-Drive In-Line Duct Blower

Designed for indoor clean air applications including intake, exhaust, return, or make-up air systems in industrial or commercial buildings. Rugged construction allows fan to be installed in ductwork either horizontally or vertically. Duct collars provide easy duct connections. Access panels are included on each side of the unit. Select unit with drive package.

  • Aluminum backward inclined, nonoverloading centrifugal wheel design
  • UL/cUL 705 Listed for Power Ventilators
  • Maximum inlet air temperature: 160º F
  • Bearing and motor cover provide longer service life
  • Regreaseable pillow block bearings

Agency Compliance

Performance

Motor HPMax BHPFan RPMCFM @
0.000'' SP0.125'' SP0.250'' SP0.375'' SP0.500'' SP0.625'' SP0.750'' SP0.875'' SP1.000'' SP1.250'' SP1.500'' SP1.750'' SP2.000'' SP2.250'' SP2.500'' SP
1/4
0.26
1292
CFM
Sones
1/3
0.35
1427
CFM
Sones
1/2
0.52
1627
CFM
Sones
3/4
0.79
1872
CFM
Sones
1
1.05
2057
CFM
Sones
1 1/2
1.57
2351
CFM
Sones
0.000'' SP0.125'' SP0.250'' SP0.375'' SP0.500'' SP0.625'' SP0.750'' SP0.875'' SP1.000'' SP1.250'' SP1.500'' SP1.750'' SP2.000'' SP2.250'' SP2.500'' SP
172816501562146013261168955
11.911.811.611.311.111.010.6
19081842175816771573144913061122
13.813.613.413.112.912.712.512.0
2176212120451978190318151708159214611087
16.115.815.515.315.014.714.313.913.512.6
25042456239823322274221121382053196017531480
21.020.019.619.218.818.518.317.917.216.014.8
2751270826612598254324902432236522942125193516981364
25.023.022.022.022.021.020.020.019.818.718.018.018.5
314431063069302029652917287128252771265325072351210819771720
35.030.028.028.027.027.025.023.024.023.022.022.022.024.027.0
Agency Compliance

Dayton Electric Mfg. Co. certifies that the blowers shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: Free inlet hemispherical fan sone levels.

Product Specifications (Glossary)

Agency Compliance [?]
  • UL/cUL 705
  • AMCA Sound & Air
Bearing Type [?]Sealed Pillow Block
CFM [?]955 to 3,144 ft3/min
Depth [?]21 in
Drive Package Description [?]Drives By Others
Drive Type [?]Belt Drive
Fan DescriptionInline Fan
Height [?]21 in
Horsepower [?] 1/4 to 1 1/2 hp
Housing Material [?]Galvanized Steel
Impeller Diameter (Nom.) [?]13 in
Impeller Material [?]Aluminum
Impeller Type [?]Backward Inclined Centrifugal
Includes [?]Access Panels
Inlet Width x Inlet Height [?]17 7/8 x 17 7/8 in
Max Inlet Temp [?]160 °F
Model DescriptionCentrifugal Belt-Drive In-Line Duct Blower
Mounting Location [?]Inline
Outlet Width x Outlet Height [?]17 7/8 x 17 7/8 in
Shaft Diameter [?] 3/4 in
Speed Controllable [?]No
TypeCentrifugal Belt-Drive, Less Drive Package
Warranty Length [?]1 Year
Width [?]21 in

Footer