Quick Links

Español | Available From: Grainger US Acklands Grainger Grainger Mexico

Header

Navigation

Content

Item Details - 3ATV2

DaytonAssembled Centrifugal Belt-Drive Upblast Exhaust Ventilator

Designed for use in restaurants, schools, commercial, and industrial applications to exhaust contaminated air from kitchen range hoods, up and away from the roof. Leakproof, spun aluminum construction features a fully rolled windband for increased stability.

  • Aluminum backward inclined, nonoverloading centrifugal wheel design
  • Maximum inlet air temperature: 300º F
  • NEMA 1 junction box located in motor enclosure
  • Optional NEMA 1 and 4 disconnects available
  • Regreaseable pillow block bearings
  • UL/cUL 705 Listed for Power Ventilators
  • UL/cUL 762 Listed for Restaurant Exhaust Appliances
  • Air handling quality bearings meet minimum of L10-100,000 hours

Agency Compliance

Performance

Motor HPMax BHPFan RPMCFM @
0.000'' SP0.125'' SP0.250'' SP0.375'' SP0.500'' SP0.625'' SP0.750'' SP0.875'' SP1.000'' SP1.250'' SP1.500'' SP1.750'' SP2.000'' SP
5
5.21
905
CFM
Sones
0.000'' SP0.125'' SP0.250'' SP0.375'' SP0.500'' SP0.625'' SP0.750'' SP0.875'' SP1.000'' SP1.250'' SP1.500'' SP1.750'' SP2.000'' SP
14,72714,49714,26614,03613,78813,50513,22312,94012,61411,96311,19110,3579178
32.032.032.030.029.029.028.028.028.027.026.024.022.0
Agency Compliance

Dayton Electric Mfg. Co. certifies that the ventilators shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.

Catalog 405, January 2010

Recommended Accessories

Adjustable, Canted Roof Curb
3C597
Item
Adjustable, Canted Roof Curb
3C598
Item
Adjustable, Straight-Sided Roof Curb
2ZV85
Item
Adjustable, Ventilated Roof Curb
4HX63
Item
Fixed, Canted Roof Curb
4HX43
Item
Fixed, Canted Roof Curb
4HX51
Item
Fixed, Straight-Sided Roof Curb
2RB81
Item
Fixed, Ventilated Roof Curb
4HX59
Item
Disconnect Switch
1H401
Item
Disconnect Switch
1H409
Item
Thermostat Switch
2E940
Item
Grease Collector
48C174
Item
Hinge Kit
4YY85
Item
Gravity Backdraft Damper
4HX69
Item
*Not for
 use in
 kitchen
 applications
Clean-out Port Kit
3ATV9
Item
Bird Screen
4YY82
Item

Product Specifications (Glossary)

Agency Compliance [?]
  • UL/cUL 762
  • AMCA Sound & Air
  • CSA Certified Motor
Assembled [?]TRUE
Base Height [?]1 3/4 in
Bearing Type [?]Regreaseable Pillow Block
CFM [?]9,178 to 14,727 ft3/min
Curb Cap Size [?]42 in
Damper Width x Damper Height [?]35 x 35 in
Drive Package Description [?]Drives Assembled
Drive Type [?]Belt Drive
Fan DescriptionExhaust Fan
Full Load Amps [?]
Height [?]40 in
Hertz (Cycle) [?]60 Hz
Horsepower (Typ.) [?]5 hp
Housing Material [?]Spun Aluminum
Impeller Diameter (Nom.) [?]30 in
Impeller Material [?]Aluminum
Impeller Type [?]Backward Inclined Centrifugal
Includes [?]NEMA 1 Junction Box
Max Inlet Temp [?]300 °F
Model DescriptionAssembled Centrifugal Belt-Drive Upblast Exhaust Ventilator
Motor Enclosure [?]Open Drip Proof
Motor Insulation [?]B
Motor Phase [?]3
Motor Type [?]
Mounting Location [?]Roof
Motor Nominal Efficiency0 %
Overall Diameter [?]50 in
Recommended Damper Size35 x 35
Required Accessory [?]Roof Curb For New Installation
Roof Opening Width x Roof Opening Length [?]37 1/2 x 37 1/2 in
Shaft Diameter [?]1 in
Speed Controllable [?]No
TypeCentrifugal Belt-Drive Upblast, Assembled
Voltage [?]208-230/460
Warranty Length [?]1 Year

Footer