Quick Links

Español | Available From: Grainger US Acklands Grainger Grainger Mexico

Header

Navigation

Content

Item Details - 3GY68

DaytonAssembled Centrifugal Belt-Drive Downblast Exhaust Ventilator

Designed to meet the general clean air exhaust requirements for industrial and commercial buildings. Features a fully rolled windband bead for increased stability and easy transport. Fresh outside air is drawn in under the motor cover to maximize motor life.

  • Aluminum backward inclined, nonoverloading centrifugal wheel design
  • Maximum inlet air temperature: 180º F
  • NEMA 1 junction box located in motor enclosure
  • Optional NEMA 1 and 4 disconnects available
  • Regreaseable pillow block bearings
  • Air handling quality bearings meet minimum of L10-100,000 hours
  • UL/cUL 705 Listed for Power Ventilators

Agency Compliance

Performance

Motor HPMax BHPFan RPMCFM @
0.000'' SP0.125'' SP0.250'' SP0.375'' SP0.500'' SP0.625'' SP0.750'' SP0.875'' SP1.000'' SP1.250'' SP1.500'' SP
2
2.06
910
CFM
Sones
0.000'' SP0.125'' SP0.250'' SP0.375'' SP0.500'' SP0.625'' SP0.750'' SP0.875'' SP1.000'' SP1.250'' SP1.500'' SP
83558135791677007467721569336616624053883707
24.023.021.021.021.020.019.619.419.216.713.6
Agency Compliance

Dayton Electric Mfg. Co. certifies that the ventilators shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.

Catalog 405, January 2010

Recommended Accessories

Adjustable, Canted Roof Curb
4C455
Item
Adjustable, Canted Roof Curb
3C438
Item
Adjustable, Straight-Sided Roof Curb
2ZV84
Item
Fixed, Canted Roof Curb
4HX42
Item
Fixed, Canted Roof Curb
4HX50
Item
Fixed, Straight-Sided Roof Curb
2RB80
Item
Adapter
3AZK6
Item
Adapter
3AZL3
Item
Disconnect Switch
1H401
Item
Disconnect Switch
1H409
Item
Hinge Kit
4YY84
Item
Gravity Backdraft Damper
4HX68
Item

Product Specifications (Glossary)

Agency Compliance [?]
  • UL/cUL 705
  • AMCA Sound & Air
  • CSA Certified Motor
Assembled [?]TRUE
Base Height [?]1 3/4 in
Bearing Type [?]Regreaseable Pillow Block
CFM [?]3,707 to 8,355 ft3/min
Curb Cap Size [?]34 in
Damper Width x Damper Height [?]27 x 27 in
Drive Package Description [?]Drives Assembled
Drive Type [?]Belt Drive
Fan DescriptionExhaust Fan
Full Load Amps [?]6.2-6.2/3.1
Height [?]38 3/8 in
Hertz (Cycle) [?]60 Hz
Horsepower (Typ.) [?]2 hp
Housing Material [?]Spun Aluminum
Impeller Diameter (Nom.) [?]24 in
Impeller Material [?]Aluminum
Impeller Type [?]Backward Inclined Centrifugal
Includes [?]NEMA 1 Junction Box
Max Inlet Temp [?]180 °F
Max. Operating Amps [?]6.2/3.1
Model DescriptionAssembled Centrifugal Belt-Drive Downblast Exhaust Ventilator
Motor Enclosure [?]Open Drip Proof
Motor Insulation [?]B
Motor Phase [?]3
Motor Type [?]
Mounting Location [?]Roof
Motor Nominal Efficiency81.5 %
Overall Diameter [?]42 3/4 in
Recommended Damper Size27 x 27
Required Accessory [?]Roof Curb For New Installation
Roof Opening Width x Roof Opening Length [?]29 1/2 x 29 1/2 in
Shaft Diameter [?]1 in
Speed Controllable [?]No
SuffixG
TypeCentrifugal Belt-Drive Downblast, Assembled
Voltage [?]208-230/460
Warranty Length [?]1 Year

Footer