DaytonCentrifugal Belt-Drive Upblast Wall-Mount Exhaust Ventilator

Designed for use in restaurants, schools, commercial, and industrial applications to exhaust contaminated air from kitchen range hoods, up and away from the roof. Leakproof, spun aluminum construction features a fully rolled windband for increased stability. Select unit with drive package.

  • Aluminum backward inclined, nonoverloading centrifugal wheel design
  • Maximum inlet air temperature: 300º F
  • NEMA 1 junction box located in motor enclosure
  • Optional NEMA 1 and 4 disconnects available
  • Sealed pillow block bearings
  • UL/cUL 705 Listed for Power Ventilators
  • UL/cUL 762 Listed for Restaurant Exhaust Appliances
  • Air handling quality bearings meet minimum of L10-100,000 hours

Agency Compliance

Performance

Motor HPMax BHPFan RPMCFM @
0.000'' SP0.125'' SP0.250'' SP0.375'' SP0.500'' SP0.625'' SP0.750'' SP0.875'' SP1.000'' SP1.250'' SP1.500'' SP
1/4
0.26
1410
CFM
Sones
1/3
0.34
1545
CFM
Sones
1/2
0.48
1725
CFM
Sones
0.000'' SP0.125'' SP0.250'' SP0.375'' SP0.500'' SP0.625'' SP0.750'' SP0.875'' SP1.000'' SP1.250'' SP1.500'' SP
16651595152814631398131512241111968
11.111.612.212.512.612.712.712.512.3
182417601699163915801518144113581262990
12.813.414.014.514.714.814.914.914.914.6
20371979192318691816176317101642157114061176
15.616.116.717.317.918.218.418.718.718.618.4
Agency Compliance

Dayton Electric Mfg. Co. certifies that the ventilators shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.

Catalog 405, January 2010

Recommended Accessories

Adapter
6KWJ5
Item

Product Specifications (Glossary)

Agency Compliance [?]
  • UL/cUL 762
  • AMCA Sound & Air
Assembled [?]FALSE
Base Diameter [?]19 3/4 in
Bearing Type [?]Sealed Pillow Block
CFM [?]968 to 2,037 ft3/min
Damper Width x Damper Height [?]12 x 12 in
Drive Package Description [?]Drives By Others
Drive Type [?]Belt Drive
Fan DescriptionExhaust Fan
Height [?]24 7/8 in
Horsepower [?] 1/4 to 1/2 hp
Housing Material [?]Spun Aluminum
Impeller Diameter (Nom.) [?]12 in
Impeller Material [?]Aluminum
Impeller Type [?]Backward Inclined Centrifugal
Includes [?]
  • NEMA 1 Junction Box
  • Mounting Plate
Max Inlet Temp [?]300 °F
Model DescriptionCentrifugal Belt-Drive Upblast Wall-Mount Exhaust Ventilator
Mounting Location [?]Wall
Overall Diameter [?]24 7/8 in
Recommended Damper Size12 x 12
Shaft Diameter [?] 3/4 in
Speed Controllable [?]No
TypeCentrifugal Belt-Drive Upblast, Less Drive Package
Warranty Length [?]1 Year