Download PDF for Print 11/22/2024

Centrifugal Belt-Drive Upblast Exhaust Ventilator

Item

Designed for use in restaurants, schools, commercial, and industrial applications to exhaust contaminated air from kitchen range hoods, up and away from the roof. Leakproof, spun aluminum construction features a fully rolled windband for increased stability.

  • Aluminum backward inclined, nonoverloading centrifugal wheel design
  • Maximum inlet air temperature: 300º F
  • NEMA 1 junction box located in motor enclosure
  • Optional NEMA 1 and 4 disconnects available
  • Regreaseable pillow block bearings
  • UL/cUL 705 Listed for Power Ventilators
  • UL/cUL 762 Listed for Restaurant Exhaust Appliances
  • Air handling quality bearings meet minimum of L10-100,000 hours
Item
ABCD
34 in42 3/4 in39 1/2 in25 1/2 in

Performance Characteristics

Item

Construction Features

Impeller Diameter (Typ.)24 1/2 in
Impeller TypeBackward Inclined Centrifugal
Impeller MaterialAluminum
Max Inlet Temp300 °F
Bearing TypeRegreaseable Pillow Block
Drive Package DescriptionDrives By Others
Warranty Length1 Year

Air & Sound Performance

Motor HPMax BHPFan RPMCFM @0.000'' SP0.125'' SP0.250'' SP0.375'' SP0.500'' SP0.625'' SP0.750'' SP0.875'' SP1.000'' SP1.250'' SP1.500'' SP1.750'' SP
1/40.26465CFM4216376831882162
Sones7.67.06.35.9
1/30.34510CFM4623424337173134
Sones8.98.17.36.9
1/20.52585CFM53034961454040933565
Sones11.510.59.58.88.4
3/40.79670CFM6074576354615052465942023524
Sones14.313.412.812.211.511.010.6
11.04735CFM66636370613357645409503746184073
Sones16.615.915.515.114.613.913.412.9
1 1/21.57845CFM766074007184694766156304600256565282
Sones19.619.018.618.217.617.016.415.915.4
22.10930CFM84318194798577987536723369536683637557064324
Sones24.023.023.022.022.021.019.919.318.717.817.9
33.001050CFM951993099107894187758534826780057766725366726005
Sones31.031.031.031.030.029.028.026.025.024.023.022.0

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.

Catalog 405, January 2010

Agency Compliance

Dayton Electric Mfg. Co. certifies that the ventilators shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

AMCA Sound & Air
Agency Compliance
UL/cUL 762
Agency Compliance